Надежный высокомощный высоковольтный источник питания для зарядки
Получите последнюю ценуВид оплаты: | T/T |
Инкотермс: | FOB,CFR,CIF,EXW |
Количество минимального заказа: | 1 Piece/Pieces |
транспорт: | Ocean,Land,Air,Express |
Порт: | SHANGHAI,NANJING,QINGDAO |
Вид оплаты: | T/T |
Инкотермс: | FOB,CFR,CIF,EXW |
Количество минимального заказа: | 1 Piece/Pieces |
транспорт: | Ocean,Land,Air,Express |
Порт: | SHANGHAI,NANJING,QINGDAO |
Модель: CCPS
марка: ИДЕАЛТЕКНИК
место происхождения: Китай
Выходная мощность: > 500 Вт
Тип выхода: Одинокий
Input Voltage: Three Phase 380vac
Input Frequency: 50/60hz
Working Principle: Pwm
Power Supply Type: Igbt-Based
Working Mode: Constant Voltage / Constant Current
Display Mode: Lcd
Control Mode: 10-Turn Potentiometers
Protections: Input Lack Phase, Ovp, Ocp, Otp, Short-Circuit Protections Etc., Ocp, Short Circuit And Load Dischargin
Applications: Capacitor Charging, Electrostatic Precipitator, Semiconductor Process, Lab Test / Hipot / Capacitor Charging
Cooling: Forced Air Cooling
Circuit Mode: Pwm
Output Voltage Range: 5 Kv ~ 60 Kv
Output Current Range: 100 Ma ~ 2400 Ma
Продажа единиц жилья | : | Piece/Pieces |
Тип упаковки | : | Фанерный ящик |
Пример с картинкой | : | |
Скачать | : |
Источник питания постоянного тока для зарядки высоковольтных конденсаторов серии CCPS
Обзор
Высоковольтный источник питания серии CCPS-6U - это модернизированная версия высоковольтных источников питания для зарядки конденсаторов CCP-6U. Он использует 19-дюймовое стандартное шасси высотой 6U, устанавливаемое в стойку, с выходной мощностью до 10 кВт и уровнем выходного напряжения 5 кВ / 10 кВ / 20 кВ / 30 кВ / 40 кВ / 50 кВ / 60 кВ, высоковольтные зарядные блоки питания достигли существенное увеличение зарядной емкости установленных в стойку источников питания для зарядки высоковольтных конденсаторов на основе сохранения высокой эффективности, высокой выходной скорости отклика и более быстрой защиты и самовосстановления при запуске
Передняя панель этой серии источников питания высокого напряжения для зарядки конденсаторов управляется потенциометром с ЖК-индикаторами, показывающими выходное высокое напряжение. Эта серия HVPS для зарядки конденсаторов может быть оборудована интерфейсом RS485 и управляющим программным обеспечением для управления и контроля рабочих параметров HVPS для зарядки конденсаторов.
Источник питания оснащен более комплексной защитой, обеспечивающей долгосрочную и надежную работу высоковольтного зарядного устройства конденсатора при полной нагрузке, например: потеря фазы на входе, перенапряжение на выходе, перегрузка по току, перегрев, защита от короткого замыкания и т. Д., И может также иметь разрядную схему для работы в условиях высоковольтной зарядки и разрядки для эффективной защиты высоковольтных источников питания и тестируемых конденсаторов.
Функции
л Может использоваться как источник питания постоянного тока высокого напряжения или как источник питания для зарядки конденсаторов высокого напряжения.
л Выходное напряжение регулируется от 0 до 100%
л Выходная мощность: средняя зарядка при 5 кДж / с, а пиковая мощность зарядки может достигать 12 кВт.
л Зарядка в режиме постоянного тока и переключение в режим постоянного тока до полной зарядки.
л Уникальная система с двойной изоляцией, сильная защита от помех.
л Принудительное воздушное охлаждение, очень прочная конструкция.
Приложения
Зарядка конденсаторов, Электростатический фильтр, Полупроводниковый процесс.
Меры безопасности
1. Этот силовой модуль имеет высоковольтный выход, работать с ним может только профессионал.
2. Перед работой убедитесь в надежном заземлении.
3. Источник питания для зарядки конденсатора имеет низкую внутреннюю накопленную энергию, пожалуйста, НЕ работайте без нагрузки.
4. Содержите силовой модуль в чистоте и хорошей вентиляции.
5. Входные и выходные разъемы ВН или нагрузка ВН ничего не трогайте.
Input |
Connection mode |
Three-phase, four-wire (PE), TN-S supply mode |
|
Voltage |
380Vac±10% |
||
Frequency |
50Hz/ 60Hz ± 10% |
||
Current |
As per output power. |
||
Output |
Rated power |
6KW ~ 12KW (Max.) available ** |
|
Output voltage adjusting range |
5KV ~ 60KV available ** (For other output voltages, please contact us for details) |
||
Output current adjusting range |
0A ~ ****mA |
||
Output polarity |
Positive or Negative (both available) Client must choose one output polarity before ordering. |
||
Working mode |
Constant voltage (CV) / Constant current (CC) |
||
Accuracy (C.V.) |
Line regulation |
≤0.5% FS ± 1 digit (Output voltage change rate only caused by changes of input voltage over ± 10% range of variation) |
|
Load regulation |
≤1% FS ± 1 digit (Output voltage change rate only caused by full range load changes) |
||
Accuracy (C.C.) |
Line regulation |
≤0.5% FS ± 1 digit (Output voltage change rate only caused by changes of input voltage over ± 10% range of variation) |
|
Load regulation |
≤0.5% FS ± 1 digit (Output voltage change rate only caused by full range load changes) |
||
Temperature drift |
≤0.03% FS (Output voltage change rate every 8 hours after power on for half an hour) |
||
Ripple (p-p) |
≤0.5% FS (measured @ 80% ~ 100% rated output) |
||
Output cable |
HV connector and line provided by IdealTek. |
||
Efficiency |
≥90% |
||
Setting & Display |
Control mode |
Local |
10-turn potentiometer on front panel. |
Remote (Optional) |
RS485 communication interface. In line with MODBUS-RTU standard. The user can control and monitor the power supply via RS485 connection with computer, E.g: l Power ON / OFF l Output voltage & current setting & reading. l Working state monitoring (constant voltage, constant current, fault) |
||
Display mode |
41/2 LCD digital display |
||
Display error |
≤±0.5%FS ± 1digit (range: 5%~100% of the rated value) |
||
Display resolution |
As per output voltage & current values. |
||
Protection & Monitoring functions |
Input protection |
Input lack phase protection. |
|
Output over voltage protection (OVP) |
Power supply automatically cuts off output and alarms when output has over voltage. |
||
Output over current protection (OCP) |
Power supply automatically cuts off output and alarms when the output has over current. |
||
Over temperature protection (OTP) |
Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds its threshold value. |
||
Output short-circuit protection |
Power supply automatically switches to CC working when the output has short-circuit. |
||
Over-loading capacity |
Withstand working with 1.05 times of rated current. |
||
Noise |
≤65dB |
||
Protection degree |
IP20 |
||
Cooling method |
l Forced air cooling l Forced air cooling + internal water-cooling loop. Direction: The lower part of the left and right sides - In and Top - Out wind. Differ as per output power rating. |
||
Inverter transient protection response time |
≤10us |
||
Working environment conditions |
Ambient temperature |
-5℃~+45℃ |
|
Humidity |
10%~80%(non-condensing) |
||
Height |
≤1000m |
||
Location |
Indoor use only No conductive dust, gas or steam that destroys the insulating medium No severe vibration and shock, good ventilation. |
||
Size (W*H*D) (mm) |
482*265.5*566.5 (19” 6U standard chassis) |
||
Weight |
Approx. 45Kg |
||
|
Front panel description |
||||||||
|
||||||||
No. |
Name |
Function |
Operation / display instruction |
|||||
F1 |
Control cabinet air inlet |
Control cabinet heat dissipation air inlet |
Keep it clean and smooth |
|||||
F2 |
Handle |
For moving and lifting purpose |
|
|||||
F3 |
Mounting hole |
For cabinet installing and fixing |
|
|||||
F4 |
POWER switch |
Supply electric ON/OFF switch |
Switch to ON position è Power ON Switch to OFF position è Power OFF |
|||||
F5 |
VOLTAGE |
Output voltage real-time display |
Digital LED display |
|||||
F6 |
CURRENT |
Output current real-time display |
Digital LED display |
|||||
F7 |
Indicator lights |
Real-time indication of module working state |
Indicator lights display |
|||||
F8 |
Voltage Adj. |
Output voltage adjusting |
Turn as icon, clockwise adjusting for increasing output voltage, anticlockwise adjusting for decreasing output voltage. |
|||||
F9 |
Current Adj. |
Output current adjusting |
Turn as icon, clockwise adjusting for increasing output current, anticlockwise adjusting for decreasing output current. |
|||||
F10 |
Analog port |
232/485 optional port (N/A for this unit) |
Please connect to DB9 port for communication with host. |
|||||
F11 |
Start/Stop (with lock) |
HV output start/stop |
Press down (green light ON) è HV START Press up (green light OFF) è HV STOP |
|||||
F12 |
Charging/Charged |
Charging / Charged state indicator light |
Charging lighted è Under charging. Charged lighted è Charging finished. |
|||||
Front Panel Indicator Lights Description |
||||||||
|
||||||||
No. |
Name |
Function |
Operation / display instruction |
|||||
F13 |
Host indicator light |
Green LED light, lighted when power supply works as host unit under multi-unit parallel-working. Note: host indicator light lighted under single-unit working. |
Indicator lights display |
|||||
F14 |
Slave indicator light |
Green LED light, lighted when power supply works as slave unit under multi-unit parallel-working. Note: slave indicator light not lighted under single-unit working. |
Indicator lights display |
|||||
F15 |
C.V. indicator light |
Green LED light, lighted when power supply works under CV state. |
Indicator lights display |
|||||
F16 |
C.C. indicator light |
Green LED light, lighted when power supply works under CC state. |
Indicator lights display |
|||||
F17 |
Flashover indicator light |
Red LED light, lighted when power supply output has disruptive discharging. |
Indicator lights display |
|||||
F18 |
OC indicator light |
Red LED light, lighted when power supply has internal inverter output over current. |
Indicator lights display |
|||||
F19 |
Out short indicator light |
Red LED light, lighted when power supply has output short-circuits. |
Indicator lights display |
|||||
F20 |
OP indicator light |
Red LED light, lighted when output power of high voltage power supply exceeds the limit. |
Indicator lights display |
|||||
F21 |
Inhibit indicator light |
Red LED light, lighted when power output is prohibited by client's external nodes. |
Indicator lights display |
|||||
F22 |
OT indicator light |
Red LED light, lighted when power supply has internal module over temperature. |
Indicator lights display |
|||||
F23 |
Grid indicator light |
Red LED light, lighted when power supply has input abnormal (i.e.: lack phase or out of scope) |
Indicator lights display |
|||||
F24 |
IGBT indicator light |
Red LED light, lighted when power supply has internal inverter fault |
Indicator lights display |
|||||
F25 |
OV indicator light |
Red LED light, lighted when output voltage goes out of scope. |
Indicator lights display |
|||||
F26 |
Load OC indicator light |
Red LED light, lighted when output current goes out of scope. |
Indicator lights display |
|||||
F27 |
APS indicator light |
Red LED light, lighted when internal auxiliary power supply is working. |
Indicator lights display |
|||||
Back panel description |
||||||||
|
||||||||
No. |
Name |
Function |
Operation / display instruction |
|||||
B1 |
GND |
Main circuit part, connected to earth. |
Separately connected to earth. |
|||||
B2 |
HV cabinet (Feedback) air socket |
For connection of HV cabinet and control cabinet. |
Connect to control cabinet (Feedback) air plug |
|||||
B3 |
Control cabinet (H-power) air socket |
For connection of control cabinet and HV cabinet. |
Connect to HV cabinet (H-power) air plug |
|||||
B4 |
Control cabinet input port |
Remote 485 signal input port |
Leave it unconnected if no 485 signal used. |
|||||
B5 |
Control cabinet DB9 port |
Remote control / reading port |
Connect in external analog signal for remote control / reading (i.e.: 0~10V) |
|||||
B6 |
Control cabinet DB15 port |
Remote start/stop, fault state TTL signal port |
Connect in external start/stop signal (i.e.: 24V) Connect in external analog signal for fault state indication (i.e.: TTL signal) |
|||||
B7 |
Control cabinet (Feedback) air socket |
For connection of control cabinet and HV cabinet |
Connect to HV cabinet (Feedback) air plug |
|||||
B8 |
Cooling fan (temperature-controlled) |
Exhaust fan, controlled by temperature inside the cabinet |
The higher the temperature inside cabinet, the faster the fan speed is. |
|||||
B9 |
IN 480V~600VDC |
Connects to DC480V~600V input |
Red is positive, black is negative. |
|||||
B10/11 |
HV-output |
Negative HV output connector |
Connection port |
|||||
B12 |
Power GND |
Positive output connector |
Connection port |
|||||
B13 |
HV cabinet (H-power) air socket |
For connection of HV cabinet and control cabinet. |
Connect to control cabinet (H-power) air plug |
|||||
Remote interface definition |
||||||||
|
||||||||
B4 Wiring diagram / B5 Internal wiring / B6 Wiring diagram |
||||||||
No. |
Name |
Function |
Operation / display instruction |
|||||
Z-1 |
485-A |
485-A |
485-A |
|||||
Z-2 |
485-B |
485-B |
485-B |
|||||
Z-3 |
Remote ON/OFF state node (optional) (N/A for this unit) |
ON/OFF state node + |
Power OFF, node closed Power ON, node open |
|||||
Z-4 |
|
ON/OFF state node - |
|
|||||
X1 |
Voltage remote control (optional) (N/A for this unit) |
Voltage remote control + |
0-10V signal for 0-15KV output voltage setting |
|||||
X2 |
|
Voltage remote control - |
|
|||||
X3 |
Current remote control (optional) (N/A for this unit) |
Current remote control + |
0-10V signal for 0-1000mA output current setting |
|||||
X4 |
KV |
mA |
P (KW) |
Model |
KV |
mA |
P (KW) |
Model |
5 |
1200 |
6 |
CCPS-(N/P)6kW-5kV |
10 |
1200 |
12 |
CCPS-(N/P)12kW-10kV |
10 |
600 |
6 |
CCPS-(N/P)6kW-10kV |
15 |
800 |
12 |
CCPS-(N/P)12kW-15kV |
15 |
400 |
6 |
CCPS-(N/P)6kW-15kV |
20 |
600 |
12 |
CCPS-(N/P)12kW-20kV |
20 |
300 |
6 |
CCPS-(N/P)6kW-20kV |
30 |
200 |
6 |
CCPS-(N/P)6kW-30kV |
30 |
167 |
5 |
CCPS-(N/P)5kW-30kV |
40 |
150 |
6 |
CCPS-(N/P)6kW-40kV |
40 |
125 |
5 |
CCPS-(N/P)5kW-40kV |
45 |
133 |
6 |
CCPS-(N/P)6kW-45kV |
50 |
100 |
5 |
CCPS-(N/P)5kW-50kV |
50 |
120 |
6 |
CCPS-(N/P)6kW-50kV |
60 |
100 |
6 |
CCPS-(N/P)6kW-60kV |
60 |
200 |
12 |
CCPS-(N/P)12kW-80kV |
|
л 0 ~ 10 В контроль аналогового сигнала (интерфейс DB) (+AC)
л Интерфейс связи RS (RS232 / RS485 необязательно) (+RC)Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.